archive-cc.com » CC » A » AIRSYSTEMS.CC

Total: 96

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Air Cylinder Carts
    Application Ventilators Ventilation Accessories Portable Lighting Air Light II Mini Cube Air Light Air Light 8600 Accessories Environmental Control Large Portable Fume Extractor Small Portable Fume Extractor Electric HEPA Vacuums Pneumatic HEPA Vacuums Air Systems Main Menu Air Systems International About Our Company Shows and Expos User Manuals MSDS Distributor Locator Contact Us Hablamos Español Warranty Information Resources FAQs Patents Trademarks Literature Training Videos Catalog Request Warranty Registration Card Fill Compressor Quote Request Plant Air Compressor Quote Request ISO 9001 Certificate Connect with us on porno izle liseli porno porno FAQs Air Cylinder Carts Print Email Q How long can a worker breathe on a cart A This depends on the respirator and the size of the air cylinder If Positive Pressure pressure demand respirators divide 4 CFM into the Cylinder CFM capacity the resulting answer is the number of minutes the worker can breathe Q What size cylinders are available A Cylinders come in a variety of air pressures and capacities Most common sized small cylinders 45 cubic ft 60 cubic ft and 87 cubic ft pressures of 2216 PSI up to 4500 PSI Large cylinders 300 cubic ft 444 cubic ft 472 cubic ft and 509 cubic ft

    Original URL path: http://www.airsystems.cc/index.php/faq-sp-266368416/16-air-cylinder-carts (2016-02-17)
    Open archived version from archive

  • Compressors
    buy a compressor specifically designed for breathing air A No While we would like to say yes the answer is no as long as the compressor is well maintained and has good clean ambient intake air free from gas and particulate contamination and is not using PAO or harmful synthetic lubricating oils Breathing air filtration package and CO monitor must be used on existing compressors Q What is the difference between a breathing air compressor and a plant air compressor A Breathing air compressor systems are designed with respirator use as the focused utility The size of the compressor FDA Food grade lubricating oil Grade D filtration CO monitor refrigerated dryer receiver tank with condensation drain and air distribution system must be specifically sized for the number of workers and types of respirators in use A plant compressor is not Q Must I use an oilless air compressor for breathing air supply A No With the advent of the FDA Food grade oil and the advances in compressor and breathing air filtration standard rotary screw piston and vane type compressor can be used when filtered with the proper filtration Q How many workers can I hook up to a compressor A This depends on the respirator used Every NIOSH approved respirator MUST free flow a minimum of 15 CFM cubic feet per minute Constant flow hoods have a flow range of 6 15 CFM Full face constant flow respirators have a flow range of 4 15 CFM Positive pressure pressure demand respirators have a flow range of 4 15 CFM Pressures vary from 6 120 PSI pounds per square inch Consult the respirator manufacturer for specific pressures flows and hose lengths Take the number of workers or respirators and multiply by the desired flow required at the pressure needed by

    Original URL path: http://www.airsystems.cc/index.php/faq-sp-266368416/135-compressor-faq (2016-02-17)
    Open archived version from archive

  • Filtration
    with us on porno izle liseli porno porno FAQs Filtration Print Email Q Why do I need filtered air A OSHA CFR 29 1910 134 regulations specify workers breathing air quality by referencing the Compressed Gas Association s G 7 1 1989 description of air quality for respiration as GRADE D breathing air To achieve that quality the air must be filtered for particulates oil aerosols and offensive odors Additionally the air must be monitored for Carbon Monoxide an odorless colorless and tasteless gas that can be fatal if inhaled in quantities Our filtration products provide GRADE D air and monitor for Carbon Monoxide Q What size filtration do I need A This depends on the number and size of the respirators to be used Once you decide how many workers need respiratory protection you will need to decide what type of respirator will be used based on the worker s risk exposure Q How long will the filters last A Filter contamination depends on the quality of the incoming air The more contaminants the air contains the shorter the filter s life will be Q How do I know when to change the filters A Each filter has a Filter Change Indicator located on the filter housing As the filter becomes contaminated the indicator gradually changes from GREEN to Orange When completely Orange the filter needs to be replaced If the filter indicators do not change within a 12 month period all the filters should be replaced Q Can my filtration work with all respirators A Yes All type C Supplied Air Respirators will work when attached to our filtration products Q What pressure should my regulator be set at A Consult the Operations Manual from the respirator manufacturer The regulator is adjustable from 0 125 PSI and it

    Original URL path: http://www.airsystems.cc/index.php/faq-sp-266368416/134-filtration-faq (2016-02-17)
    Open archived version from archive

  • Air Systems Inc.
    Cart Rescue Air Carts The Air Responder Multi Air Command Kits SCBA Storage Custom Trailers Ventilation The Original Saddle Vent The Conductive Saddle Vent Hazardous Location Ventilators Non Hazardous Location Ventilators Confined Space Carts Special Application Ventilators Ventilation Accessories Portable Lighting Air Light II Mini Cube Air Light Air Light 8600 Accessories Environmental Control Large Portable Fume Extractor Small Portable Fume Extractor Electric HEPA Vacuums Pneumatic HEPA Vacuums Air Systems

    Original URL path: http://www.airsystems.cc/index.php/component/contact/ (2016-02-17)
    Open archived version from archive

  • Air Systems Inc.
    Saddle Vent The Conductive Saddle Vent Hazardous Location Ventilators Non Hazardous Location Ventilators Confined Space Carts Special Application Ventilators Ventilation Accessories Portable Lighting Air Light II Mini Cube Air Light Air Light 8600 Accessories Environmental Control Large Portable Fume Extractor Small Portable Fume Extractor Electric HEPA Vacuums Pneumatic HEPA Vacuums Air Systems Main Menu Air Systems International About Our Company Shows and Expos User Manuals MSDS Distributor Locator Contact Us

    Original URL path: http://www.airsystems.cc/index.php/component/contact/category/12-administration (2016-02-17)
    Open archived version from archive

  • Air Cylinder Carts
    sized small cylinders 45 cubic ft 60 cubic ft and 87 cubic ft pressures of 2216 PSI up to 4500 PSI Large cylinders 300 cubic ft 444 cubic ft 472 cubic ft and 509 cubic ft pressures of 2400 PSI up to 6000 PSI Q Why should I use a cart A Very rarely does one single source of air supply satisfy all breathing applications Bottled air is NOT subject

    Original URL path: http://www.airsystems.cc/index.php/faq-sp-266368416/16-air-cylinder-carts?tmpl=component&print=1&page= (2016-02-17)
    Open archived version from archive

  • Air Systems Inc.
    Email this link to a friend Close Window Email to Sender Your Email Subject Send Cancel

    Original URL path: http://www.airsystems.cc/index.php/component/mailto/?tmpl=component&template=asi25&link=38ac694ae7fb0a3d68da7d12f3ed4e56f8ffdf7d (2016-02-17)
    Open archived version from archive

  • Compressors
    FDA Food grade lubricating oil Grade D filtration CO monitor refrigerated dryer receiver tank with condensation drain and air distribution system must be specifically sized for the number of workers and types of respirators in use A plant compressor is not Q Must I use an oilless air compressor for breathing air supply A No With the advent of the FDA Food grade oil and the advances in compressor and breathing air filtration standard rotary screw piston and vane type compressor can be used when filtered with the proper filtration Q How many workers can I hook up to a compressor A This depends on the respirator used Every NIOSH approved respirator MUST free flow a minimum of 15 CFM cubic feet per minute Constant flow hoods have a flow range of 6 15 CFM Full face constant flow respirators have a flow range of 4 15 CFM Positive pressure pressure demand respirators have a flow range of 4 15 CFM Pressures vary from 6 120 PSI pounds per square inch Consult the respirator manufacturer for specific pressures flows and hose lengths Take the number of workers or respirators and multiply by the desired flow required at the pressure needed by the respirator and the answer will give you the necessary CFM for the compressor Q What is the difference between pressure and flow A Pressure is force described in PSI Pascals or Bars Flow is the volume or quantity of air described in CFM cubic feet per minute liters per minute cubic meters per minute or hour Q What is an ambient air pump A An ambient air pump is an oilless vane air compressor operating at low pressure not exceeding 15 PSIg operating constant flow respirators only Q Who regulates the use of compressors A OSHA in their

    Original URL path: http://www.airsystems.cc/index.php/faq-sp-266368416/135-compressor-faq?tmpl=component&print=1&page= (2016-02-17)
    Open archived version from archive