archive-cc.com » CC » A » AIRSYSTEMS.CC

Total: 96

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Point-of-Attachments
    Ventilators Ventilation Accessories Portable Lighting Air Light II Mini Cube Air Light Air Light 8600 Accessories Environmental Control Large Portable Fume Extractor Small Portable Fume Extractor Electric HEPA Vacuums Pneumatic HEPA Vacuums Air Systems Main Menu Air Systems International About Our Company Shows and Expos User Manuals MSDS Distributor Locator Contact Us Hablamos Español Warranty Information Resources FAQs Patents Trademarks Literature Training Videos Catalog Request Warranty Registration Card Fill Compressor Quote Request Plant Air Compressor Quote Request ISO 9001 Certificate Connect with us on porno izle liseli porno porno Point of Attachments View Catalog Page and Ordering Info View Download User Manual A remote air manifold is often called a Point of Attachment POA All of our remote air manifolds meet NIOSH requirements of the 87 116 1989 document for point of attachment The Point of Attachment POA series provides remote manifold capability for respirator users while complying with NIOSH regulations The POA series consists of a regulator pressure gauge safety relief valve and fitting congruency necessary for proper respirator operation The POA box can be located any distance from the Grade D filtration Breather Box or filtration panel The remote air manifold POA assembly becomes the NIOSH attachment point for the respirators and is now limited to a maximum of 300 feet of breathing air hose at the air outlet fitting on the remote POA box Remote Air Manifolds Point of Attachments POA Specifications Adjustable regulator 1 2 Industrial Interchange male inlet plug Pressure gauge 0 160psi Safety relief valve set at 125psi 1 4 respirator couplings supplied with safety locks Aluminum block manifold Water resistant polycarbonate case Rubber gasketed lid helps to prevent internal contamination Unit can be taken into wet or hazardous locations Using POA units you can move the NIOSH point of attachment for airline respirators

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-38-35/remote-air-manifolds (2016-02-17)
    Open archived version from archive

  • Breathing Air Accessories
    BB15 FKW Replacement particulate filter Stage 1 Replacement coalescing filter Stage 2 Replacement charcoal filter Stage 3 Filter kit for BB15 CO series models Contain 1 ea A C and D replacement filter BB50 Series BB50 A BB50 C BB50 D BB50 FK Replacement particulate filter Stage 1 Replacement coalescing filter Stage 2 Replacement charcoal filter Stage 3 Filter kit for BB50 CO series models Contain 1 ea A C and D replacement filter BB30 Series BB30 A BB30 C BB30 D BB30 FK Replacement particulate filter Stage 1 Replacement coalescing filter Stage 2 Replacement charcoal filter Stage 3 Filter kit for BB30 CO series models Contain 1 ea A C and D replacement filter BB75 Series BB75 A BB75 C BB75 D BB75 FK Replacement particulate filter Stage 1 Replacement coalescing filter Stage 2 Replacement charcoal filter Stage 3 Filter kit for BB75 CO series models Contain 1 ea A C and D replacement filter BB100 Series BB100 A BB100 C BB100 D BB100 FK Replacement particulate filter Stage 1 Replacement coalescing filter Stage 2 Replacement charcoal filter Stage 3 Filter kit for BB100 CO series models Contain 1 ea A C and D replacement filter Airline Monitor Calibration Kits Air Systems Carbon Monoxide Oxygen Calibration kits are available in two sizes 17 liter and 103 liter The cylinders are disposable All airline monitors should be calibrated on a monthly basis or if the accuracy of the monitor is in question Use only Air Systems gas concentration or an inaccurate calibration may occur BBK 20 17 Liter Cylinder BBK 20103 103 Liter Cylinder Use only Genuine Air Systems Calibration Gas when replacing cylinders BBG 00 BBG 20 View Catalog Page and Ordering Info QUICK CONNECT COUPLINGS ٠Hansen٠Schrader٠Parker٠Snap Tite٠National٠Perfecting٠CEJN٠Chicago٠Breco Specify size and type when ordering breathing air systems and hoses

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-38-35/breathing-air-accessories (2016-02-17)
    Open archived version from archive

  • Air Quality Testing
    Español Warranty Information Resources FAQs Patents Trademarks Literature Training Videos Catalog Request Warranty Registration Card Fill Compressor Quote Request Plant Air Compressor Quote Request ISO 9001 Certificate Connect with us on porno izle liseli porno porno Air Quality Testing View Catalog Page and Ordering Info Air Sampling Kits Air Quality Testing The Responsibility for the Quality of Breating air Rests with the User The air supply compressor should be located in a safe clean ambient air environment This safe location should be tested periodically to ensure clean ambient air quality on a consistent basis Total system air quality should be tested at the time the compressor is initially set up If the compressor is moved retesting air quality is recommended Should the location or environment significantly change the air quality should be retested AirCheck Kit Certified laboratory air testing is now available for high pressure bottled air or low pressure compressor air requirements Take your own samples in 10 minutes and send out for precise laboratory results A 2LA accredited lab will test to any recognized standards e g CGA NFPA or Federal MIL Specs Results can be obtained in less than 3 days same day service is available for an additional charge AIR SAMPLING KITS AVAILABLE FOR RENTAL OR PURCHASE Laboratory Air Testing Service Fast Easy Accurate Compressed Air Cylinder Test Kit The Model AQTCOO2KIT Cylinder Test Kit was designed to rapidly test rented cylinder s breathing air quality before use and obtain an immediate and accurate Oxygen O 2 and Carbon Monoxide CO reading for blended high pressure cylinder air The meter requires two 9 volt batteries for operation and is supplied with a 10 foot high pressure hose 5000 psi regulator and a universal CGA 347hand tight cylinder connector AQTCOO2KIT Visual Air Flowmeter to Monitor High Pressure

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-38-35/air-quality-testing (2016-02-17)
    Open archived version from archive

  • Custom Breathing Air Systems
    Cart Rescue Air Carts The Air Responder Multi Air Command Kits SCBA Storage Custom Trailers Ventilation The Original Saddle Vent The Conductive Saddle Vent Hazardous Location Ventilators Non Hazardous Location Ventilators Confined Space Carts Special Application Ventilators Ventilation Accessories Portable Lighting Air Light II Mini Cube Air Light Air Light 8600 Accessories Environmental Control Large Portable Fume Extractor Small Portable Fume Extractor Electric HEPA Vacuums Pneumatic HEPA Vacuums Air Systems Main Menu Air Systems International About Our Company Shows and Expos User Manuals MSDS Distributor Locator Contact Us Hablamos Español Warranty Information Resources FAQs Patents Trademarks Literature Training Videos Catalog Request Warranty Registration Card Fill Compressor Quote Request Plant Air Compressor Quote Request ISO 9001 Certificate Connect with us on porno izle liseli porno porno Custom Breathing Air Systems View Catalog Page Custom Designed Filtration Systems Air Systems engineering and design team will manufacture a custom Grade D breathing air system to meet your most stringent needs BB650 COPM 650cfm Grade D Filtration Plant Filtration Systems are Available up to 3000cfm Custom Plant Breathing Air Grade D Filtration for Clean Room Applications Explosion Proof Grade D System Model B50 COPMEX 50cfm explosion proof Grade D Filtration supplied with NEMA 7

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-38-35/explosion-proof-filtration (2016-02-17)
    Open archived version from archive

  • Compressors
    Technical Rescue Cart Rescue Air Carts The Air Responder Multi Air Command Kits SCBA Storage Custom Trailers Ventilation The Original Saddle Vent The Conductive Saddle Vent Hazardous Location Ventilators Non Hazardous Location Ventilators Confined Space Carts Special Application Ventilators Ventilation Accessories Portable Lighting Air Light II Mini Cube Air Light Air Light 8600 Accessories Environmental Control Large Portable Fume Extractor Small Portable Fume Extractor Electric HEPA Vacuums Pneumatic HEPA Vacuums

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-39-27 (2016-02-17)
    Open archived version from archive

  • Portable Breathing Air
    This compressor is not designed for use with constant flow respirators or Vortex cooling tubes All compressors MUST be placed in a clean air environment per OSHA 1910 134 Comp 3 Breathing Air Compressor System Designed for use with Pressure Demand Respirators Only TA 3 Compressor Specifications Rotary vane air compressor rated for continuous duty Pressure range to 110psi output 2 HP electric motor 1750rpm continuous duty thermally protected 115 230 VAC 1 phase 60Hz 17 2 amps Requires 20amp service Low maintenance 500 hours between oil changes 10 pneumatic tires 50 000 hour minimum vane life Built in skid plate for stair climbing USDA approved food grade oil in compression end Automatic pressure unloading full modulation air control Breather Box Grade D filtration package required Noise level below 70 dbA at 3 feet 8 Gallon Twin Air tank assembly 8 5cf air storage 110psi ASME coded 1 2 5000 series Hansen style coupling on air outlet Optional explosion proof motor 230 3 VAC only Model TA 3EXP Dimensions 46 L x 24 W x 22 H Weight 150 lbs Model COMP 1 Shown above with TA 1 Compressor and BB15 CO Breather Box Comp 1 Breathing Air Compressor System Designed for use with Two Pressure Demand Respirators Only The TA 1 compressor has been designed to operate 1 or 2 pressure demand airline respirators Grade D filtration must be provided in the form of a 1 or 2 worker Breather Box The TA 1 uses a 115 230 VAC 60 Hz electrical supply Model TA 3G uses gasoline engine for mobile operations USDA food grade oil is used in the compressor air end This compressor is not designed for use with constant flow respirators or Vortex cooling tubes View Catalog Page and Ordering Info Compressors for use in IDLH

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-39-27/portable-breathing-air (2016-02-17)
    Open archived version from archive

  • Ambient Air Pumps
    not designed for use with pressure demand respirators or Vortex cooling tubes due to low output pressure BAC 10 2 Worker Air Pump Specifications Operates 1 hood style respirator or 2 tight fitting constant flow masks Respirator requirements CANNOT exceed maximum pressure of 15psi Maximum 10psi at 9cfm output 9 5cfm output at 4psi Electric motor 3 4 HP ODP 100 115 208 230 VAC 12 2 6 1 amps 50 60 Hz 1 phase thermally protected CSA approved 0 5 0 7 micron inlet and compressor filters 0 30psi pressure gauge Prewired with on off switch and plug 115 VAC plug only Approximate weight 55 lbs Specifications Operates 2 hood style respirators or 3 tight fitting constant flow masks as long as the combined flow requirements DO NOT exceed 15cfm at 4psi Maximum pressure 15psi at 12 cfm output 15 cfm at 4psi Electric motor 1 5 HP TEFC 115 208 230 VAC 15 2 8 2 amps 60 Hz 1 phase thermally protected CSA approved Prewired with on off switch and plug 115 VAC plug only 0 30psi pressure gauge 0 5 0 7 micron inlet and compressor filter Approximate weight 96 lbs Optional explosion proof electric motor available Model BAC 17EXP 230 460 3 phase motor BAC 17 3 Worker Air Pump BAC 20 4 Worker Air Pump Specifications Operates 2 hood style respirators or 4 tight fitting constant flow masks Maximum pressure 15psi at 16 cfm output 20 cfm at 4psi Electric motor 2 HP TEFC 115 208 230 VAC 20 0 10 0 amps 60 Hz 1 phase thermally protected CSA approved Prewired with on off switch and plug 115 VAC 0 5 0 7 micron inlet and compressor filter 0 30psi pressure gauge Approximate weight 103 lbs Note BAC 17 BAC 20 AND BAC

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-39-27/ambient-air-pumps (2016-02-17)
    Open archived version from archive

  • COOL-BOX™
    Light 8600 Accessories Environmental Control Large Portable Fume Extractor Small Portable Fume Extractor Electric HEPA Vacuums Pneumatic HEPA Vacuums Air Systems Main Menu Air Systems International About Our Company Shows and Expos User Manuals MSDS Distributor Locator Contact Us Hablamos Español Warranty Information Resources FAQs Patents Trademarks Literature Training Videos Catalog Request Warranty Registration Card Fill Compressor Quote Request Plant Air Compressor Quote Request ISO 9001 Certificate Connect with us on porno izle liseli porno porno Personal Cooling View Catalog Page and Ordering Info View Download the User Manual The COOL BOX Portable Cooling Air Distribution Manifold Features Provides approximately 50 F output air temperature with input temperatures up to 180 F Provides 4 to 8 hours of cooling using 20 lbs of ice for operation Manual condensate drain installed inside Attaches to any Grade D compressed air source up to 125psi Adjustable pressure regulator gauge and safety relief valve installed in the system with a final filter on Model BACB 196 Entire unit is packaged in a rugged Igloo roller cooler with a fold down pull handle Low Pressure Model BACB 196LP Maximum Pressure 20psi Benefits Provides low cost cool breathing air anywhere Operates with any airline Type C

    Original URL path: http://www.airsystems.cc/index.php/2009-03-24-20-39-27/personal-cooling (2016-02-17)
    Open archived version from archive